How to use human serotonin (5-HT) ELISA kit
2024-10-31 13:04:27
This kit is for research use only. Detection range: 96T80ng / L-2400 ng / L Purpose: This kit is used to determine the content of serotonin (5-HT) in human serum, plasma and related liquid samples. Experimental principle The kit uses the double antibody sandwich method to determine the level of human serotonin (5-HT) in the specimen. A microplate was coated with purified human serotonin (5-HT) antibody to make a solid-phase antibody. Serotonin (5-HT) was added to the microwells coated with mAb in turn, followed by HRP-labeled serotonin ( 5-HT) The antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with serotonin (5-HT) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human serotonin (5-HT) in the sample was calculated by a standard curve. Kit composition 1 30-fold concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle 2 enzyme label reagent 6ml × 1 bottle 8 standard (4800 ng / L) 0.5ml × 1 bottle 3 enzyme label coated plate 12 wells × 8 strips 9 standard diluent 1.5ml × 1 bottle 4 sample diluent 6ml × 1 bottle 10 instruction manual 1 copy 5 developer A solution 6ml × 1 bottle 11 sealing film 2 sheets 6 developer B solution 6ml × 1 / Bottle 12 Sealed bag 1 specimen requirement 1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity. Procedure 1. Dilution of standard product: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart. 2400 ng / L No. 5 standard 150μl original standard added 150μl standard dilution 1200ng / L No. 4 standard 150μl standard No. 5 added 150μl standard dilution 600ng / L No. 3 standard 150μl No. 4 Add 150μl standard dilution 300ng / L No. 2 standard 150μl No. 3 standard add 150μl standard dilution 150ng / L No. 1 standard 150μl No. 2 standard add 150μl standard dilution 2. Add sample : Set up blank wells (the blank control wells do not add samples and enzyme-labeled reagents, the rest of the operations are the same), standard wells, and sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix. 3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes. 4. Mixing solution: Dilute the 30-fold concentrated washing solution with distilled water 30-fold and reserve for use. 5. Washing: Carefully remove the sealing film, discard the liquid, spin dry, fill each well with the washing solution, and let it stand for 30 seconds before discarding , Repeat this 5 times, pat dry. 6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well. 7. Incubation: The operation is the same as 3. 8. Washing: The operation is the same as 5. 9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop color at 37 ° C in the dark 15 minutes. 10. Stop: Add 50μl of stop solution to each well to stop the reaction (the blue color turns to yellow at this time). 11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Silicone Beauty & Hair Salon Tool
Silicone Beauty & Hair Salon Tool,Facial Mask Mixing Bowl,Silicone Hair Dye Cap,Scalp Massager
DONGGUAN BILLION GOODTOP INDUSTRIAL CO., LTD , https://www.bgoodtop.com