Human CD3, CD4, CD8 ELISA Kit For the quantitative in vitro determination of Human CD3, CD4, CD8 concentrations in serum - plasma - celiac fluid - tissue homogenate - body fluid FOR LABORATORY RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. Insert must be read in its entirety before using this product. ELISAENZYME LINKED IMMUNOSORBENT ASSAYINTENDED USE AND TEST PRINCIPLEThis CD3, CD4, CD8 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. Color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of CD3, CD4, CD8 in the sample, this CD3, CD4, CD8 ELISA Kit includes a set of calibration standards The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus CD3, CD4, CD8 concentration. The concentration of CD3, CD4, CD8 In the samples is then determined by comparing the OD of the samples to the standard curve. SAMPLE COLLECTION AND STORAGESSerum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4°C before centrifugation for 20 minutes at Approximately 2000×g. Remove serum and assay immediately or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cyclesPlasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8°C within 30 minutes of collection. Store samples at -20°C. Avoiding freeze-thaw cycles. Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20°C. -thaw cycles.Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.MATERIALS REQUIRED BUT NOT SUPPLIED1. 37 °C incubator2. Standard microplate reader capa Ble of measuring absorbance at 450 nm3. Precision pipettes, disposable pipette tips and Absorbent paper4. Distilled or deionized waterREAGENTS PROVIDED All reagents provided are stored at 2-8°C. Refer to the expiration date on the label. Name 96 determinations 48 determinationsMicroelisa stripplate 12*8strips 12*4stripsStandard(6 vial) 0.5ml/vial 0.5ml/vialSample diluent 6.0ml 3.0mlHRP-Conjugate reagent 10.0ml 5.0ml20X Wash solution 25ml 15mlChromogen Solution A 6.0ml 3.0mlChromogen Solution B 6.0ml 3.0mlStop Solution 6.0ml 3.0 mlClosure plate membrane 2 2User manual 1 1Sealed bags 1 1Note: 1. Standard concentration was followed by: 200, 100, 50, 25, 12.5, 6.25 ng/mL2. If samples generate values ​​higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.PRECAUTIONS1. Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by ma 2. nufacturer. 2. Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents. 3. Do not use kit components beyond their expiration date. 4. Use only 5. Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided. 6. Use fresh disposable pipette tips for each 8. Dis notable acid and sodium hypochlorite solutions. 8. Disumable plasma must be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer Complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed. 9. All samples should be dis 10. The Waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal. 11. Substrate Solution 12. Abstrate B contain 20% acetone, keep this reagent away from sources of heat or flame. 13. Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).REAGENT PREPARATION AND STORAGEWash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C. ASSAY PROCEDURE1 Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.2. Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn't add anyting.3. Add 100μl of HRP-conjugate reagent to Standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.4. Wash the Microtiter Plate 4 times.Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or Proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate Note: Hold the sides of the plate frame firm when washing the plate to assure that all strips remain securely in frame. Automated Washing - Aspirate all wells, then Adjust plates four times using Wash Buffer (1X). always adjust your massage to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.6. Add 50μl Stop Solution to each well If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing. 7. Read the Optical Density (OD) at 450 The standard curve is generated by plotting the average OD (450 nm) obtained for each of the six standard concentrations On the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis. 2. First, calculate the mean OD value for each standard and sample. All OD Values ​​are subtracted by the mean value of the balnk well before result interpretation Construct the To determine the amount in each sample, first locate the OD value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to 4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.5. Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.6. Assay range: 6.25ng/ml –200 ng/ml.7. Sensitivity: The minimum detectable dose of Human CD3,CD4,CD8 is typically Less than 1.0 ng/ml8. Cross-reactivity: This assay recognizes recombinant and natural Human CD3, CD4, CD8. No significant cross-reactivity or interference was observed.9. Storage: 2-8°C (Use frequently); six months ( -20 ° C). 10. QUOTE READ ONH;
Ribbon Baby Pacifier Clips
Ribbon Baby Pacifier Clips is a multi use appease chain. it is a great helper to fix baby's pacifiers,no worry about the teether or pacifier to get lost on the ground. Beaded Baby Pacifier Clips will not affect the development of the baby's teeth, and let the baby grow healthily and happily. Ribbon baby Pacifier Clips is used for baby under 3 month. Please Always check first to see cord and beads are intact before giving to your baby. Not intended to be used as a toy. This clip has small parts and could be a choking hazard.
For more: Silicone Teething Beads, Silicone baby teether, silicone baby pacifier clips, Baby Teething Mitten , Baby Teething Necklace.
Ribbon Baby Pacifier Clips
Ribbon Baby Pacifier Clips,Pacifier Clip,Silicone Pacifier Clip,Baby Soother Pacifier Clips
Shenzhen Kean Silicone Product Co., Ltd. , https://www.keansilicon.com