GB / T 1408.1-2006
Voltage breakdown tester-microcomputer control
DDJ-100KV
fulfill the standard:
GB1408-2006 Test method for electrical strength of insulating materials
GB / T1695-2005 vulcanized rubber power frequency voltage breakdown strength and voltage strength test
GB / T3333 Test method for cable paper power frequency voltage breakdown
HG / T 3330 Insulation paint film breakdown strength test method
GB12656 Capacitor paper power frequency voltage breakdown test method
ASTM D149 Test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials at industrial power frequency.
1. Scope and function
It is mainly suitable for the test of the breakdown strength and withstand voltage of solid insulating materials (such as plastic, rubber, film, resin, mica, ceramic, glass, insulating paint and other media) under power frequency voltage or DC voltage.
This instrument is controlled by a computer and is completed by the new intelligent digital integrated circuit system and software control system independently developed by our company, so that the boost rate is truly uniform and accurate, and can accurately measure the leakage current data. The test curve can be drawn in real time, the test data can be displayed, the judgment is accurate, and the test data can be saved, analyzed and printed.
2. Technical requirements:
01. Input voltage: AC 220 V
02. Output voltage: AC 0--100 KV;
DC 0—100 KV
03. Electrical capacity: 5KVA
04. High voltage classification: 0-10KV, 0--50KV, 0-100KV
05. Boost rate: 100V / S 200V / S 500 V / S 1000 V / S 2000V / S 5000V / S etc.
(Remarks: meet the standard requirements and can set different boost rates according to user needs)
06. Test method:
DC test: 1. Constant speed boost 2. Gradient boost 3. Withstand voltage test AC test: 1. Constant speed boost 2. Gradient boost 3. Pressure test
07. Test medium: air, test oil
08. Install an overcurrent protection device with high sensitivity to ensure that the power is cut off within 0.05S when the sample breaks down.
09. Adopt advanced non-contact original uniform pressure regulation method.
10. Support short circuit test requirements in a short time.
11. Voltage test accuracy: ≤ 1%.
12. The test voltage is continuously adjustable: 0--100 KV.
13. The current can be collected to mA level.
14. Issuing the calibration verification certificate of the 203 Institute of the Second National Aerospace Research Institute or the certificate of measurement unit designated by the customer.
3. Security protection
The circuit protection control of this test instrument:
(1) Overvoltage protection (2) Overcurrent protection (3) Short circuit protection (4) Leakage protection (5) Software misoperation protection
High voltage input circuit power-off protection control:
(1) Main power switch (2) Voltage regulator reset switch (3) High-voltage power-off switch
(4) Test box door safety switch (5) High voltage circuit switch (6) Leakage protection switch
4. Main equipment configuration
Equipment standard configuration
Serial number
name
Configuration
Remarks
01
Test host
One
02
Control device
set
03
Test electrode
Two sets (national standard 1408.1)
04
Test tank
Two
05
Discharge system
set
06
Control System
set
07
data collection system
set
08
Test software
set
CD
09
computer
set
Brand
10
Inkjet Printers
One
Brand
11
Instruction Manual
A copy
12
Measurement Certificate
A copy
13
Product certification
A copy
5. The conventional model of this equipment is:
DDJ-10KV
DDJ-20KV
DDJ-30KV
DDJ-50KV
DDJ-100KV
Crown measuring instruments, superb technology, excellent quality, excellent performance, perfect after-sales