Manual of human S100 calcium binding protein A8 / A9 complex (S100A8 / A9) kit

Human S100 Calcium Binding Protein A8 / A9 Complex (S100A8 / A9) Kit Instructions This kit is for research use only. Detection range: 96T0.3μg / L -8.0μg / L Purpose: This kit is used to determine the content of S100 calcium binding protein A8 / A9 complex (S100A8 / A9) in human serum, plasma and related liquid samples. Experimental principle The kit uses the double antibody sandwich method to determine the level of human S100 calcium binding protein A8 / A9 complex (S100A8 / A9) in the specimen. Microporous plates were coated with purified human S100 calcium binding protein A8 / A9 complex (S100A8 / A9) antibody to prepare solid-phase antibodies. S100 calcium binding protein A8 / A9 complex was added to the microwells coated with mAb in turn (S100A8 / A9), and then combined with HRP-labeled S100 calcium binding protein A8 / A9 complex (S100A8 / A9) antibody to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the S100 calcium binding protein A8 / A9 complex (S100A8 / A9) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human S100 calcium binding protein A8 / A9 complex (S100A8 / A9) in the sample was calculated by a standard curve. Kit composition 1 30-fold concentrated washing solution 20ml × 1 bottle 7 Stop solution 6ml × 1 bottle 2 enzyme label reagent 6ml × 1 bottle 8 standard (16μg / L) 0.5ml × 1 bottle 3 enzyme label coated plate 12 well × 8 strips 9 standard diluent 1.5ml × 1 bottle 4 sample diluent 6ml × 1 bottle 10 instruction manual 1 copy 5 developer A solution 6ml × 1 bottle 11 sealing film 2 sheets 6 developer B solution 6ml × 1 / Bottle 12 sealed bag 1 specimen requirement 1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity. Procedure 1. Dilution of standard product: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart. 8.0μg / L No. 5 standard 150μl original standard add 150μl standard dilution 4.0μg / L No. 4 standard 150μl No. 5 standard add 150μl standard dilution 2.0μg / L No. 3 standard 150μl Standard No. 4 added 150μl standard dilution 1.0μg / L Standard No. 2 150μl standard No. 3 added 150μl standard dilution 0.5μg / L Standard No. 1 150μl standard No. 2 added 150μl standard dilution 2. Sample addition: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the operation is the same), standard wells, sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix. 3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes. 4. Mixing solution: Dilute 30 times concentrated washing solution with distilled water 30 times and reserve for use 5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with washing solution, let it stand for 30 seconds and then discard , Repeat this 5 times, pat dry. 6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well. 7. Incubation: The operation is the same as 3. 8. Washing: The operation is the same as 5. 9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop color at 37 ° C in the dark 15 minutes. 10. Stop: add 50μl of stop solution to each well to stop the reaction (at this time, the blue will turn to yellow). 11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution. Summary of operating procedures: Calculate the concentration of the standard as the abscissa and the OD as the ordinate, draw a standard curve on the graph paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; or Calculate the linear regression equation of the standard curve using the concentration of the standard and the OD value. Substitute the OD value of the sample into the equation to calculate the sample concentration and multiply it by the dilution factor to obtain the actual concentration of the sample. Matters needing attention 1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag. 2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing. 3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples. 4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple (n times) of the sample diluent and then determine it. Please multiply the total dilution for the calculation Multiple (× n × 5). 5. The sealing film is limited to one-time use to avoid cross-contamination. 6. Please keep the substrate away from light. 7. Strictly follow the instructions, and the test results must be determined based on the reading of the microplate reader. 8. All samples, washing liquids and various wastes should be treated as infectious agents. 9. The components of different batches of this reagent shall not be mixed. Storage conditions and validity period Kit storage :; 2-8 ℃. 2. Validity: 6 months

      Stainless Steel Vacuum Flask!Best Vacuum Flask,robust,veratile and durable in use ,brushed stainless steel styling with magnetic stainless-steel base.flared rim for easy clean. non-drip pouring.,beautiful shiny appearance. high quality 18/10 stainless steel for kettle body,,raw  Material:Inner S.S304#,outter S.S 201#Vacuum Flask Near Me,Capacity:1.5L/2L/3L.Finish: Satin or Painting. Packing:use gift box packing,12pcs/ctn.

      

Stainless Steel Vacuum Flask

Stainless Steel Vacuum Flask,Stainless Steel Thermos Flask,Stainless Steel Vacuum Flask 500Ml,Stainless Steel Thermal Flask

JAPOP COMPANY LIMITED , https://www.japopkitchenware.com