Rabbit lipoprotein phospholipase A2 enzyme-linked immunoassay (ELISA)
Rabbit lipoprotein phospholipase A2 (Lp-PLA2) enzyme-linked immunoassay (ELISA)
Kit instruction manual
This kit is for research use only.
Drug Name:
Generic name: Rabbit lipoprotein phospholipase A2 (Lp-PLA2) ELISA kit
purpose of usage:
This kit is used to determine the content of lipoprotein phospholipase A2 (Lp-PLA2) in rabbit serum, plasma and related liquid samples.
Experimental principle
This kit uses an indirect method to determine the level of rabbit lipoprotein phospholipase A2 (Lp-PLA2) in the specimen. Microporous plates were coated with purified rabbit lipoprotein phospholipase A2 (Lp-PLA2) antibody to make solid-phase antibodies, and known concentrations of lipoprotein phospholipase A2 (Lp-PLA2) were added to the monoclonal antibody-coated microwells in sequence. ) Standards and Lp-PLA2 samples of unknown concentration, after incubation, add biotin-labeled anti-IgG antibody, and then combine with streptavidin-HRP to form an immune complex, and add substrate after thorough washing TMB color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with lipoprotein phospholipase A2 (Lp-PLA2) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of rabbit lipoprotein phospholipase A2 (Lp-PLA2) in the sample was calculated by a standard curve.
Kit composition
1
20 times concentrated washing liquid
50ml × 1 bottle
9
Standard product S1 (180μg / L)
0.5ml × 1 bottle
2
Streptavidin-HRP
6ml × 1 bottle
Standard product S2 (120μg / L)
0.5ml × 1 bottle
3
Enzyme coated plate
12 holes × 8
Standard product S3 (60μg / L)
0.5ml × 1 bottle
4
Biotin-labeled anti-IgG antibody
6ml × 1 bottle
Standard product S4 (30μg / L)
0.5ml × 1 bottle
5
Developer A liquid
6ml × 1 bottle
Standard product S5 (15μg / L)
0.5ml × 1 bottle
6
Developer B liquid
6ml × 1 / bottle
10
sealed bag
1
7
Stop solution
6ml × 1 bottle
11
Sealing film
3 sheets
8
Sample diluent
6ml × 1 bottle
12
Instructions
1 serving
Specimen requirements
1. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
2. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
Steps
1. Determine the number of slats required based on the number of samples to be tested plus the number of standards. It is recommended to make multiple holes for each standard and blank hole. Each sample is determined according to its own quantity, and those that can use multiple holes can be used for multiple holes.
2. Adding samples: set up blank wells (the blank control wells do not add samples, the rest of the operations are the same), standard wells, and sample wells to be tested. Then add 50μl of the standard to the standard well, add 10μl of the sample to be tested to the sample reaction well and then add 40μl of the sample diluent (the final dilution of the sample is 5 times). Incubate for 45 minutes.
3. Mixing solution: dilute 20 times concentrated washing solution with distilled water 20 times and reserve
4. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing solution, let stand for 30 seconds and then discard, repeat 4 times, pat dry.
5. Add biotin-labeled anti-IgG antibody: Add 50 μl of biotin-labeled anti-IgG antibody to each well. Incubate at 37 ° C for 30 minutes
6. Washing: The operation is the same as 4.
7. Add streptavidin-HRP: add 50μl streptavidin-HRP to each well, gently shake and mix, and incubate at 37 ° C for 30 minutes.
8. Washing: The operation is the same as 4.
9. Color development: Add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Calculation
Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, put the OD value of the sample into the equation, calculate the sample concentration, and then multiply it by the dilution factor, which is the actual concentration of the sample.
Precautions
1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample by a certain multiple (n times) and then determine it. When calculating, please multiply the dilution factor (× 5 × n).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. The components of different batches of this reagent shall not be mixed. Store developer B in dark place.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. If there is any difference with the English manual, the English manual shall prevail.
Linear range:
10μg / L -200μg / L
specification:
96 servings / box
Storage conditions and validity period
1. Kit storage :; 2-8 ℃.
2. Validity: 6 months
1. Exerts uniform compression to support lower back and abdominal muscles during activities
2. Supports along the spine to provide stability for those suffering from lower back pain
3. You can wear it either under or outside of clothes
4. Soft, Reusable, Collapsible, Shockproof, Eco-friendly, Stain Resistance,Soft touching feel
Weightlifting Waist Support,Waist Guard,Sport Waist Trainer ,Fat Sport Waist Support,Waist Sweat Wrap,Waist Trimmer
Shijiazhuang AoFeiTe Medical Devices Co., Ltd. , https://www.aofit.com